PHARMA STATIONS NETWORK

 

AirBridgeCargo Airlines has built extended network of international pharma stations working with reliable partners and providing its customers with high-quality ground and airport facilities for pharmaceutical shipments. Full list of stations and facilities.

 EUROPE:

FRA  HHN  AMS  CDG  XCR  LHR  BSL  MXP  BRU  LGG 

APAC:

SIN  NRT PVG  ICN  HKG  PEK TPE  

RUSSIA:

SVO 1  SVO 2  DME  KJA


STATION PROFILE: FRANKFURT - RHEIN-MAIN-FLUGHAFEN AIRPORT

  Ground Handling Agent     FCS Frankfurt
Cargo Service
 
  Working hours 24/7    yes   
  Equipment      
  Thermal dollies  
  Thermal blankets    
  ACTAC       
  Plug-in/charge source    16   
  Dry-ice on stock    No   
  Batteries on stock   No   
  Storage areas       
  CRT (+15 / +25)   315 m2  
  ULDs   16  
  COL (+2 / +8)   460 m2  
  ULDs   18  
  FRO (-10 or colder)   0 m2  
  ULDs   0  
  Certification      
  CEIV   No  
 
 TTSP Time (HH:mm)    
Export operation     Import operation
Acceptance to Cooler Build-up Cooler in to Aircraft   Unloading to Cooler Breakdown Cooler to Truck    
 0:45 1:00  0:10    1:10   0:30 1:15 


STATION PROFILE: FRANKFURT - HAHN AIRPORT 

  Ground Handling Agent     VG Cargo  
  Working hours 24/7   yes   
  ACTAC       
  Plug-in/charge source    20   
  Dry-ice on stock    No   
  Batteries on stock   On request   
  Storage areas       
  CRT (+15 / +25)   93 m2  
  ULDs   12  
  COL (+2 / +8)   93 m2  
  ULDs   12  
  FRO (-10 or colder)   0 m2  
  ULDs   0  
  Certification      
  CEIV   No  
 
 TTSP Time (HH:mm)    
Export operation     Import operation
Acceptance to Cooler Build-up Cooler in to Aircraft   Unloading to Cooler Breakdown Cooler to Truck    
 0:15 0:30  0:12    0:20  0:10  0:12 


STATION PROFILE: AMSTERDAM - SCHIPHOL AIRPORT

  Ground Handling Agent     Menzies Aviation  
  Working hours 24/7   yes   
  Equipment      
  Thermal blankets     
  ACTAC       
  Plug-in/charge source    28   
  Dry-ice on stock    No   
  Batteries on stock   Yes   
  Storage areas       
  CRT (+15 / +25)   0 m2  
  ULDs   0  
  COL (+2 / +8)   90 m2  
  ULDs   12  
  FRO (-10 or colder)   0 m2  
  ULDs   0  
  Certification      
  CEIV   No  
 
 TTSP Time (HH:mm)    
Export operation     Import operation
Acceptance to Cooler Build-up Cooler in to Aircraft   Unloading to Cooler Breakdown Cooler to Truck    
 0:30 0:30  0:15    0:05  0:25  0:10 


STATION PROFILE: PARIS - CHARLES DE GAULLE AIRPORT

  Ground Handling Agent     WFS   
  Working hours 24/7   yes   
  Equipment      
  Thermal blankets     
  Thermal dollies      
  ACTAC       
  Plug-in/charge source    10   
  Dry-ice on stock    No   
  Batteries on stock   on request  
  Storage areas       
  CRT (+15 / +25)   0 m2  
  ULDs   0  
  COL (+2 / +8)   0 m2  
  ULDs   0  
  FRO (-10 or colder)   0 m2  
  ULDs   0  
  Certification      
  CEIV   No  


STATION PROFILE: PARIS - CHÂLONS VATRY AIRPORT

  Ground Handling Agent     Paris-Vatry Airport  
  Working hours 24/7   yes   
  Equipment      
  Temperature controlled build-up/break down area   
  ACTAC       
  Plug-in/charge source    10   
  Dry-ice on stock    No   
  Batteries on stock   No   
  Storage areas       
  CRT (+15 / +25)   2500 m2  
  ULDs   15  
  COL (+2 / +8)   2500 m2  
  ULDs   15  
  FRO (-10 or colder)   4 m2  
  ULDs   0  
  Certification      
  CEIV   No  
 
 TTSP Time (HH:mm)    
Export operation     Import operation
Acceptance to Cooler Build-up Cooler in to Aircraft   Unloading to Cooler Breakdown   Cooler to Truck  
 0:00 0:00  0:05    0:20  0:00  0:00 


STATION PROFILE: LONDON - HEATHROW AIRPORT

  Ground Handling Agent     Dnata  
  Working hours 24/7   yes   
  ACTAC       
  Plug-in/charge source     
  Dry-ice on stock    No   
  Batteries on stock   No   
  Storage areas       
  CRT (+15 / +25)   0 m2  
  ULDs   0  
  COL (+2 / +8)   14 m2  
  ULDs   2  
  FRO (-10 or colder)   0 m2  
  ULDs   0  
  Certification      
  CEIV   No  
 
 TTSP Time (HH:mm)    
Export operation     Import operation
Acceptance to Cooler Build-up Cooler in to Aircraft   Unloading to Cooler Breakdown Cooler to Truck    
 0:05 0:30  0:25    0:30  0:25  0:05 


STATION PROFILE: BASEL - MULHOUSE FREIBURG AIRPORT

  Ground Handling Agent     Swissport  
  Working hours 24/7   No   
  Equipment      
  Thermal blankets       
  Temperature controlled build-up/break down area  
  ACTAC       
  Plug-in/charge source    20   
  Dry-ice on stock    No   
  Batteries on stock   Yes   
  Storage areas       
  CRT (+15 / +25)   7500 m2  
  ULDs   64  
  COL (+2 / +8)   92 m2  
  ULDs   4  
  FRO (-10 or colder)   13 m2  
  ULDs   0  
  Certification      
  CEIV   In process  
 
 TTSP Time (HH:mm)    
Export operation     Import operation
Acceptance to Cooler Build-up Cooler in to Aircraft   Unloading to Cooler Breakdown Cooler to Truck    
 0:08 0:30  0:55    0:35  1:00  0:00 


STATION PROFILE: MILAN - MALPENSA

  Ground Handling Agent     Alha MXP S.p.A.  
  Working hours 24/7   Yes   
  Equipment      
  Thermal blankets       
  ACTAC       
  Plug-in/charge source    12   
  Dry-ice on stock    No   
  Batteries on stock   Yes   
  Storage areas       
  CRT (+15 / +25)   600 m2  
  ULDs   14  
  COL (+2 / +8)   170 m2  
  ULDs   14  
  FRO (-10 or colder)   30 m2  
  ULDs   0  
  Certification      
  CEIV   Yes  
 
 TTSP Time (HH:mm)    
Export operation     Import operation
Acceptance to Cooler Build-up Cooler in to Aircraft   Unloading to Cooler Breakdown Cooler to Truck    
 0:03 0:45  0:25    0:25  1:00  0:15 


STATION PROFILE: BRUSSELS - NATIONAL AIRPORT

  Ground Handling Agent     Swissport Cargo
Service
 
  Working hours 24/7   yes   
  Equipment      
  Thermal doilies  
  Thermal blankets  
  Temperature controlled build-up/break down area  
  ACTAC       
  Plug-in/charge source    10   
  Dry-ice on stock    No   
  Batteries on stock   Yes   
  Storage areas       
  CRT (+15 / +25)   800 m2  
  ULDs   35  
  COL (+2 / +8)   1000 m2  
  ULDs   40  
  FRO (-10 or colder)   20 m2  
  ULDs   0  
  Certification      
  CEIV   Yes  
 
 TTSP Time (HH:mm)    
Export operation     Import operation
Acceptance to Cooler Build-up Cooler in to Aircraft   Unloading to Cooler Breakdown Cooler to Truck    
 0:20 0:30  1:05    0:30  0:45  0:20 


STATION PROFILE: LIÈGE - AIRPORT

  Ground Handling Agent     Aviapartner Liège  
  Working hours 24/7    yes   
  Equipment       
  Thermal blankets  
  Temperature controlled build-up / break down area  
  ACTAC       
  Plug-in/charge source    12   
  Dry-ice on stock    No   
  Batteries on stock   yes   
  Storage areas       
  CRT (+15 / +25)   200 m2  
  ULDs   8  
  COL (+2 / +8)   200 m2  
  ULDs   8  
  FRO (-10 or colder)   30 m2  
  ULDs   1  
  Certification      
  CEIV   Yes  
 
 TTSP Time (HH:mm)    
Export operation     Import operation
Acceptance to Cooler Build-up Cooler in to Aircraft   Unloading to Cooler Breakdown Cooler to Truck    
 0:35 0:30  0:30    0:10  0:30  0:20 


STATION PROFILE: SINGAPORE - CHANGI AIRPORT 

  Ground Handling Agent     SATS Coolport
95 Airport Cargo Road
 
  Working hours 24/7    Yes   
  Equipment      
  Thermal blankets      
  ACTAC       
  Plug-in/charge source    15   
  Dry-ice on stock    Yes   
  Batteries on stock   Yes   
  Storage areas       
  CRT (+15 / +25)   500 m2  
  ULDs   20  
  COL (+2 / +8)   500 m2  
  ULDs   20  
  FRO (-10 or colder)   100 m2  
  ULDs   5  
  Certification      
  CEIV   Yes  


STATION PROFILE: TOKYO - NARITA AIRPORT

  Ground Handling Agent     Nippom Cargo
Airlines Co., Ltd
 
  Working hours 24/7   Yes   
  Equipment      
  Thermal blankets      
  ACTAC       
  Plug-in/charge source    9  
  Dry-ice on stock    No  
  Batteries on stock   Yes  
  Storage areas       
  CRT (+15 / +25)   11 m2  
  ULDs   0  
  COL (+2 / +8)   294 m2  
  ULDs   6  
  FRO (-10 or colder)   10,5 m2  
  ULDs   0  
  Certification      
  CEIV   No  


STATION PROFILE: SHANGHAI - PUDONG AIRPORT 

  Ground Handling Agent     PACTL  
  Working hours 24/7   Yes   
  Equipment      
  Thermal dollies      
  Thermal blankets      
  Temperature controlled build-up/break down area  
  ACTAC       
  Plug-in/charge source    32   
  Dry-ice on stock    No   
  Batteries on stock   No   
  Storage areas       
  CRT (+15 / +25)   413 m2  
  ULDs   25  
  COL (+2 / +8)   509 m2  
  ULDs   15  
  FRO (-10 or colder)   232 m2  
  ULDs   8  
  Certification      
  CEIV   Yes  


STATION PROFILE: SEOUL - INCHEON AIRPORT

  Ground Handling Agent     ATLAS AIR CARGO  
  Working hours 24/7    yes   
  Equipment      
  Thermal blankets      
  Thermal dollies      
  ACTAC       
  Plug-in/charge source    15   
  Dry-ice on stock    No   
  Batteries on stock   Yes   
  Storage areas       
  CRT (+15 / +25)   194 m2  
  ULDs   4  
  COL (+2 / +8)   318 m2  
  ULDs   6  
  FRO (-10 or colder)   318 m2  
  ULDs   6  
  Certification      
  CEIV   No  


STATION PROFILE: HONG KONG - CHEK LAP KOK AIRPORT

  Ground Handling Agent     HACTL    
  Working hours 24/7    yes   
  Equipment      
  Thermal blankets  
  Temperature controlled build-up / break down area  
  ACTAC       
  Plug-in/charge source    10   
  Dry-ice on stock    No   
  Batteries on stock   No   
  Storage areas       
  CRT (+15 / +25)   175 m2  
  ULDs   8  
  COL (+2 / +8)   1190 m2  
  ULDs   25  
  FRO (-10 or colder)   175 m2  
  ULDs   8  
  Certification      
  CEIV   Yes  


STATION PROFILE: BEIJING - CAPITAL INTERNATIONAL AIRPORT

  Ground Handling Agent     Beijing
Aviation Ground
 
         
  ACTAC       
  Plug-in/charge source    18   
  Batteries on stock   No   
  Storage areas       
  CRT (+15 / +25)   100 m2  
  ULDs   6  
  COL (+2 / +8)   200 m2  
  ULDs   12  
  FRO (-10 or colder)   175 m2  
  ULDs   10  
  Certification      
  CEIV   No  


STATION PROFILE: TAIPEI - TAOYUAN INTERNATIONAL AIRPORT

  Ground Handling Agent     FARGLORY  
  Working hours 24/7   Yes   
  ACTAC       
  Plug-in/charge source    15   
  Dry-ice on stock    Yes   
  Batteries on stock   Yes   
  Storage areas       
  CRT (+15 / +25)   250 m2  
  ULDs   15  
  COL (+2 / +8)   222 m2  
  ULDs   15  
  FRO (-10 or colder)   75 m2  
  ULDs   4  
  Certification      
  CEIV   No  


STATION PROFILE: MOSCOW - SHEREMETYEVO AIRPORT (SVO 1) 

  Ground Handling Agent     Moscow Cargo LLC
 
  Working hours 24/7   Yes   
  Equipment      
  Thermal dollies      
  Thermal blankets      
  ACTAC       
  Plug-in/charge source    11  
  Dry-ice on stock    Yes  
  Batteries on stock   Yes  
  Storage areas       
  CRT (+15 / +25)   160 m2  
  ULDs   10  
  COL (+2 / +8)   798 m2  
  ULDs   10  
  FRO (-10 or colder)   77 m2  
  ULDs   0  
  Certification      
  CEIV   No  
 
 TTSP Time (HH:mm)    
Export operation SVO1     Import operation SVO1 
Acceptance to Cooler Build-up Cooler in to Aircraft   Unloading to Cooler Breakdown Cooler to Truck    
 1:00 1:30 0:30    1:00  1:30  0:30 


STATION PROFILE: MOSCOW - SHEREMETYEVO AIRPORT (SVO 2)

  Ground Handling Agent     Sheremetyevo
Cargo LLC
 
  Working hours 24/7   Yes   
  Equipment      
  Thermal dollies      
  Thermal blankets      
  ACTAC       
  Plug-in/charge source    10  
  Dry-ice on stock    No  
  Batteries on stock   Yes  
  Storage areas       
  CRT (+15 / +25)   297 m2  
  ULDs   0  
  COL (+2 / +8)   635 m2  
  ULDs   0  
  FRO (-10 or colder)   333 m2  
  ULDs   0  
  Certification      
  CEIV   No  
 
 TTSP Time (HH:mm)    
Export operation SVO2     Import operation SVO 2
Acceptance to Cooler Build-up Cooler in to Aircraft   Unloading to Cooler Breakdown Cooler to Truck    
 1:00 1:30 0:30    1:00  1:30  0:30 

 

 


STATION PROFILE: MOSCOW - DOMODEDOVO AIRPORT 

  Ground Handling Agent        
  Working hours 24/7   Yes   
  Equipment      
  Thermal dollies      
  Thermal blankets      
  ACTAC       
  Plug-in/charge source    20  
  Dry-ice on stock    Yes  
  Batteries on stock   Yes  
  Storage areas       
  CRT (+15 / +25)   5551 m2  
  ULDs   40  
  COL (+2 / +8)   489 m2  
  ULDs   27  
  FRO (-10 or colder)   49 m2  
  ULDs   0  
  Certification      
  CEIV   No  
 
 TTSP Time (HH:mm)    
Export operation     Import operation
Acceptance to Cooler Build-up Cooler in to Aircraft   Unloading to Cooler Breakdown Cooler to Truck    
 0:10 0:10 0:15    0:30 0:10  0:10 

 

 


STATION PROFILE: KRASNOJARSK - YEMELYANOVO AIRPORT

  Ground Handling Agent     Siberia Cargo
Service
 
  Working hours 24/7   Yes   
  Equipment      
  Thermal dollies      
  Thermal blankets   In progress   
  ACTAC       
  Plug-in/charge source    2  
  Dry-ice on stock    No  
  Batteries on stock   No  
  Storage areas       
  CRT (+15 / +25)   0 m2  
  ULDs   0  
  COL (+2 / +8)   300 m2  
  ULDs   4  
  FRO (-10 or colder)   70 m2  
  ULDs   0  
  Certification      
  CEIV   No  

FOLLOW US